Newest. Lighter. Smallest...
Online run data's, to your mobile phone!
Official site: www.tsslimiter.com
Limiter V1.1
TECHNICAL SPECIFICATION
Parameter |
Value |
Note |
Measured voltage |
0 – 44V |
DC |
Voltage measurement accuracy |
±0.1% |
|
Measured current (up to 20 sec) |
1 – 150A |
|
Measured current (DC) |
1 – 100A |
|
Current measurement accuracy |
±0.5% + ±50mA |
|
Measured energy |
0 – 300,000Wh |
|
Energy measurement accuracy |
±1.0% |
|
Temperature measurement |
-10 – +150⁰C |
Device temperature |
Temperature measurement accuracy |
±1.0⁰C |
|
Sampling frequency |
300Hz |
|
Series resistance |
0.25mOhm |
|
Current consumption |
6mA |
|
BEC voltage |
4 – 13V |
|
Type of communication interface |
BLE |
Bluetooth Low Energy 5.0 |
Communication Interface range |
100m |
In direct visibility |
Receiver signal |
0.7 – 2.3ms |
Standard PPM 3.3-10V |
Working temperature range |
0 – 50⁰C |
|
IP rating |
IP67 |
|
Dimensions of the device |
22.5 х 19.5 х 10.5mm |
No wires included |
Weight |
18g |
Including all wires and plugs |
Wire to receiver length |
240mm |
|
Wire to ESC length |
40mm |
|
Type of signal wires |
26AWG (JR) |
|
Length of the power wire |
100mm |
|
In total, the device has 14 sets of settings, 8 (6 - 14) of which are user-defined and are subject to change.
The device has 6 sets of preset settings. These settings cannot be changed and 1-5 sets fully comply with the Naviga rules.
The device is equipped with logger, which can be used as an online telemetry and as an ordinary logger, allowing you to read the meashured data after the race.
Logger and telemetry display the following parameters:
A display of the average current per race and the average voltage per race will be added soon.
The basic settings of the limiter can be changed using a button that is connected via a wire that goes to the receiver.
Functions of setting by button is given in the table:
Settings set number |
Purpose |
Energy limitation |
0 |
Training mode, telemetry only |
∞ |
1 |
Mini Eco, Mono, Hydro |
21Wh |
2 |
Eco Expert, Mono I, Hydro I |
60Wh |
3 |
Mono II, Hydro II |
120Wh |
4 |
FSR-E |
180Wh |
5 |
For tests only |
2Wh |
Function |
Parameter |
Note |
Reset of energy calculation |
Hold down for 10 ± 3 seconds |
Indication can be updated with delay in one period |
Switching the set of settings up |
Push once |
Only if the energy calculation is not started. Cyclically switching between 0–5 sets |
Switching the set of settings down |
Hold down for 1 second |
Only if the energy calculation is not started. Cyclically switching between 0–5 sets |
Password reset |
Hold down for 30 ± 10 seconds |
Only if the energy calculation is not started. |
Manual start of bootloader |
Hold down before switching on, release as soon as the green LED goes out |
In normal device operation it is not used. Required if there are problems with updating the firmware in a regular manner. |
Complet of delivery:
1. TSS limiter V.1.1
2. Ajustment Bottom